Specification
DC Supply:
8.0 V to 35 V Continuous.
Cranking Dropouts:
Able to survive 0 V for 50mS, providing supply was at least 10 V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries.
Max. Operating Current:
(all inputs outputs active except fuel / start)
320mA at 12V, 215mA at 24V
Max. Standby Current:
(all inputs outputs active except fuel / start)
175mA at 12V, 95mA at 24V
Alternator Input Range:
Single phase 2 wire system
3Phase 4Wire System
15 V AC - 300 V AC (ph-N) (+20%)
15 V AC - 300 V AC (ph-N) (+20%)
Alternator Input Frequency:
50Hz - 60 Hz at rated engine speed
Magnetic Input Range:
(if fitted) +/- 0.5 V to 70 V Peak
Magnetic Input Frequency:
10,000 Hz (max) at rated engine speed.
Start Relay Output:
16 Amp DC at supply voltage.
Fuel Relay Output:
16 Amp DC at supply voltage.
Auxiliary Relay Outputs:
5 Amp DC at supply voltage.
Dimensions:
240mm x 172mm x 57mm (9.5” x 6.8” x 2.3”)
Panel cut-out:
220mm x 160mm ( 8.7” x 6.3”)
Maximum panel thickness:
8mm (0.3”)
Charge Fail / Excitation Range:
0 V to 35 V
Operating Temperature Range:
-30 to +70°C
C.T. Burden 2.5VA (see note)
C.T. Secondary 5A
C.T. Class Class 1 or better recommended
Electromagnetic Compatibility:
BS EN 61000-6-2 EMC Generic Emission Standard (Industrial)
BS EN 61000-6-4 EMC Generic Immunity Standard (Industrial)
Electrical Safety:
BS EN 60950 Safety of I.T. equipment, including electrical business equipment.
Cold Temperature:
BS EN 60068-2-1 to -30 oC
Hot Temperature:
BS EN 60068-2-2 to +70oC
Humidity:
BS60068-2-38 to 93% RH @ 40°C for 48 Hours
Vibration:
BS EN60068-2-6
10 sweeps at 1 octave/minute in each of 3 major axes.
5Hz to 8Hz @ +/-7.5mm constant displacement
8Hz to 500Hz @ 2gn constant acceleration
Shock:
BS EN 2011-2-1
3 Half sine shocks in each of 3 major axes
15gn amplitude, 11mS duration
NOTE: Although the 5110’s burden on the measurement C.T.’s is 2.5VA, the required C.T. rating will need to be higher depending upon the type and length of cabling used. For further details see the Appendix section entitled "Choosing the correct C.T.'s" elsewhere in this manual.
Part Photos
Fast and Safe Delivery
You can choose the delivery term which is appropriate for you.
More Related Generator Controller
High-Quality generator controller used for Cummins, Deep Sea, FG Wilson, Monicon, ComAp and more.
More Generator Set Parts
You can find many generator set parts on our website. Meanwhile you can also contact us with your part number and we will check for you. Welcome to make inquiry to us directly.